Product Catalog
Standard Basis
Industry basis
Surge Simulator PSUG-20T1
PSUG-20T1 is specially designed for the requirements of electromagnetic compatibility - surge (impact) (SUG) immunity test. It is used to evaluate the performance of power cords and internal connecting wires of electrical and electronic equipment when they are subjected to high-energy transient interference caused by switches and natural lightning strikes.
Product series: Products
Product series: Lightning Surge Simulator
Product series: EMC/EMS
Product series: Solution
Product series: EMC EMS
Product series: + GB/T17626.5
Product series: IEC standard
Product series: + IEC61000-4-5
Product series: Industry
Product series: Electricity
- Details
- 满足标准
- 技术参数
-
PSUG-20T1 is specially designed for the requirements of electromagnetic compatibility - surge (impact) (SUG) immunity test. It is used to evaluate the performance of power cords and internal connecting wires of electrical and electronic equipment when they are subjected to high-energy transient interference caused by switches and natural lightning strikes.
>Support multi-channel testing
>Positive and negative polarity can be switched freely
>One-button switch between Chinese and English modes
>Built-in international standard grade parameters
>Excellent craftsmanship, durable
>The maximum test voltage can reach 20000V
>10.1-inch color touch screen operation
>Built-in temperature and humidity, time, real-time high-voltage display
>Phase angle asynchronous or 0~360°free setting
>Surge test mode full-speed automatic switching
>Built-in RJ45 interface, remote control (optional)
>Built-in high-voltage differential probe and current transformer can measure waveform
>IEC/EN60664
>GB/T17626.5/IEC61000-4-5
>ITU K20
>ANSIC62.41/45
>GB/T16927.1
>IEC/EN 61643-1
>ITU K44
>ITU K45
Product model
PSUG-20T1
Open circuit voltage
2000V ~ 20000V± 10%
Voltage resolution
100V
Rise time
1.2μs ±30%
Duration
50μs ±20%
Short circuit current
1000 A~10000A ±10%
Rise time
8μs ±20%
Duration
20μs ±20%
Output polarity
+,-,+/-, -/+
Output impedance
2 Ω
Step voltage
0~20000V
Interval Time
5s~9999s
Test times
1c~60000c
Trigger mode
Manual, external, interval trigger
Phase synchronization
0°~359°(50 HZ or 60 HZ) (Synchronous Asynchronous)
Build-in CDN
Coupling
1-phase 3-wire coupling
Decoupling Load
UAC MAX 240V /16A UDC MAX 220V/16A
Coupling capacitor
9μF(L-PE)、 18μF(L-L)
Coupling resistor
12 Ω、2 Ω
Residual pulse voltage at the injection end of the tested equipment
Not more than 15% of the applied test pulse voltage or twice the rated voltage peak of the coupling/decoupling network
Key words:
Previous Page
Product Message
Related Products