Products

Product Catalog

Standard Basis

Industry basis

CAN Line CDN PDATA-CDN-4S

The lightning surge signal line network PDATA-CDN-4S is specially designed for the requirements of electromagnetic compatibility - surge (impact) (SUG) immunity test, and is used for lightning surge signal line networks of unshielded symmetrical interconnection lines. Perform surge tests on the communication ports of the equipment under test.

Product series: Products

Product series: EMC/EMS

Product series: Solution

Product series: EMC EMS

Product series: EMC System

Product series: Standards

Product series: GB/T standards

Product series: IEC standard

Product series: + GB/T17626.5

  • Details
  • 满足标准
  • 技术参数
  • Product Model

    PDATA-CDN-4S

    Open Circuit Voltage

    1.2/50μs

     

    10/700μs

    Short Circuit Current

    8/20μs  

     

    5/320μs

    Maximum Voltage

    6.0kV

    Current Limiting Resistor

    25R,40R,80R,160R

    Network Decoupling Inductor

    20mH

    Coupling Device

    0.5uF,90V  Gas Discharge Tube

    Communication

    100M

Key words:

Product Message