Product Catalog
Standard Basis
Industry basis
Conducted Susceptibility(CS) PCRF-80P0
The PCRF-80P0 conducted immunity generator is a comprehensive test system for RF conducted and radiated immunity tests. It can meet the test requirements of IEC61000-4-6 (Electromagnetic Compatibility Part 4: Experiments and Measurement Techniques Part 6: Immunity Test for Conducted Interference Induced by Radio Frequency Fields) through different module configurations. It evaluates the working reliability and stability of electronic equipment in a conducted noise interference environment. It can help detect the immunity of equipment to external interference sources (such as power lines, communication cables, etc.) and provide data and results for engineering design and improvement.
Product series: EMC System
Product series: EMC EMS
Product series: Standards
Product series: Products
Product series: EMC/EMS
Product series: Conducted Susceptibility (CS) System
Product series: Solution
Product series: GB/T standards
Product series: + GB/T17626.6
Product series: IEC standard
- Details
- 满足标准
- 技术参数
-
The PCRF-80P0 conducted immunity generator is a comprehensive test system for RF conducted and radiated immunity tests. It can meet the test requirements of IEC61000-4-6 (Electromagnetic Compatibility Part 4: Experiments and Measurement Techniques Part 6: Immunity Test for Conducted Interference Induced by Radio Frequency Fields) through different module configurations. It evaluates the working reliability and stability of electronic equipment in a conducted noise interference environment. It can help detect the immunity of equipment to external interference sources (such as power lines, communication cables, etc.) and provide data and results for engineering design and improvement.
> 150kHz-230MHz full frequency band adjustable
> Chinese and English switchable
> Built-in industrial computer, can directly connect to printer, mouse, keyboard and USB flash drive, etc.
> Excellent workmanship, durable
> The maximum output signal level can reach 30V (149.5 dBμV), which can realize the scanning of signal level while sweeping frequency
> GB/T17626.6/IEC61000-4-6
PCRF-80P0
Output voltage
1~30Vrms(CDN method)
1~18Vrms(electromagnetic clamp method)
Test levels
1V,3V,10V,X(customized)
Output impedance
50Ω
VSWR
≤1.2
Frequency range
9kHz~3GHz
Step mode
Linear step(0.1~100MHz)
Proportional step(0.2~10%)
Dwell time
0.5s~60s
Power
-60dBm~10dBm
Non-modulated signal
Constant Amplitude Continuous Wave
Modulation mode
Amplitude modulation frequency
frequency:1Hz~100kHz
Depth:1~100%
Pulse modulation frequency
frequency:1Hz~100kHz
Duty cycle:1~100%
Input power
-25dBm~+20dBm
Maximum output power
+49dBm/80W
Harmonic
≤-30 dBc/<15dBc
Output interface
N type (female)
General specification
Display screen
10.1 inch
Working power
AC 220V ± 10% 50/60Hz
mbient temperature
5℃~35℃
Ambient humidity
45%~75%
Atmospheric pressure
86kPa~106 kPa
Instrument power
200W
Size
450*222*550
Weight
30kg
working status indication
Front panel LED indicators