High Power EFT CDN PEFT-CDN-3100/3200-690

​​​​​​​​PEFT-CDN-3100/3200-690 high-voltage and high-power pulse group coupling and decoupling network can meet the AC/DC power supply pulse group test and realize automatic three-phase coupling and decoupling function. The maximum load capacity of EUT is AC 690 V 100 A/200A, DC 1000 V 100A/200 A three-phase five-wire. Other EUT voltage and current levels can be customized according to customer requirements.

Product series: Products

Product series: EMC/EMS

Product series: Solution

Product series: EMC EMS

Product series: Standards

Product series: GB/T standards

Product series: IEC standard

Product series: + GB/T17626.4

Product series: + IEC61000-4-4

Product series: EFT/Burst Simulator

  • Details
  • 满足标准
  • 技术参数
  • ​PEFT-CDN-3100/3200-690 high-voltage and high-power pulse group coupling and decoupling network can meet the AC/DC power supply pulse group test and realize automatic three-phase coupling and decoupling function. The maximum load capacity of EUT is AC 690 V 100 A/200A, DC 1000 V 100A/200 A three-phase five-wire. Other EUT voltage and current levels can be customized according to customer requirements.

     

    > EUT Load Max DC 1000 V 100A/200 A

    > EUT Load Max AC 690 V 100A/200 A 3-phase 5 wires

    >Overcurrent protection

    > High-power aviation plug, safe and reliable

    > Built-in international standard grade parameters, easy to operate

    >Pulse injection phase angle asynchronous or 0-360° free setting 

    >Pulse frequency can reach up to 1200kHz, and the frequency can be increased

    >Built-in RJ45 interface, optional measurement and control software for remote control

     

    > IEC/EN61850-3

    > ANSI/IEEE C62.41

    > GB/T 17626.4/IEC 61000-4-4

    > IEC/EN61000-6-1

    > EC/EN 60601-1-2

    Model

    ​PEFT-CDN-3100/3200-690

    Voltage output range

    200V~5000V±10%  

    Voltage resolution

    1V

    Voltage Step

    1V

    Voltage accuracy

    <±10%

    Output polarity

    +,-,+/-,  -/+

    T&H

    Built-in thermometer and humidity meter

    Source impedance

    50Ω

    Rise time

    5ns±30%

    Duration

    50ns±30%    50Ω  Load

    35ns~150ns  1000Ω Load

    Frequency range

    0.1kHz~1200kHz

    Frequency resolution

    0.1kHz

    Standard frequency

    5kHz、100kHz

    Pulse group duration

    0.001~2550.000ms

    Pulse group period

    300ms ( 0.15~99.99 s)

    Test duration

    1s~9999s

    Direct output mode

    Through high-voltage coaxial connector

    Phase synchronous

    0°~359°(45 HZ~ 65 HZ)

    (synchronous, automatic, asynchronous))

    Coupling

    Built-in 3-phase 5-wire coupling

    UAC MAX 690V /200A   UDC MAX 1000V/200A

Key words: