Product Catalog
Standard Basis
Industry basis
High Power EFT CDN PEFT-CDN-3100/3200-690
PEFT-CDN-3100/3200-690 high-voltage and high-power pulse group coupling and decoupling network can meet the AC/DC power supply pulse group test and realize automatic three-phase coupling and decoupling function. The maximum load capacity of EUT is AC 690 V 100 A/200A, DC 1000 V 100A/200 A three-phase five-wire. Other EUT voltage and current levels can be customized according to customer requirements.
Product series: Products
Product series: EMC/EMS
Product series: Solution
Product series: EMC EMS
Product series: Standards
Product series: GB/T standards
Product series: IEC standard
Product series: + GB/T17626.4
Product series: + IEC61000-4-4
Product series: EFT/Burst Simulator
- Details
- 满足标准
- 技术参数
-
PEFT-CDN-3100/3200-690 high-voltage and high-power pulse group coupling and decoupling network can meet the AC/DC power supply pulse group test and realize automatic three-phase coupling and decoupling function. The maximum load capacity of EUT is AC 690 V 100 A/200A, DC 1000 V 100A/200 A three-phase five-wire. Other EUT voltage and current levels can be customized according to customer requirements.
> EUT Load Max DC 1000 V 100A/200 A
> EUT Load Max AC 690 V 100A/200 A 3-phase 5 wires
>Overcurrent protection
> High-power aviation plug, safe and reliable
> Built-in international standard grade parameters, easy to operate
>Pulse injection phase angle asynchronous or 0-360° free setting
>Pulse frequency can reach up to 1200kHz, and the frequency can be increased
>Built-in RJ45 interface, optional measurement and control software for remote control
> IEC/EN61850-3
> ANSI/IEEE C62.41
> GB/T 17626.4/IEC 61000-4-4
> IEC/EN61000-6-1
> EC/EN 60601-1-2
Model
PEFT-CDN-3100/3200-690
Voltage output range
200V~5000V±10%
Voltage resolution
1V
Voltage Step
1V
Voltage accuracy
<±10%
Output polarity
+,-,+/-, -/+
T&H
Built-in thermometer and humidity meter
Source impedance
50Ω
Rise time
5ns±30%
Duration
50ns±30% 50Ω Load
35ns~150ns 1000Ω Load
Frequency range
0.1kHz~1200kHz
Frequency resolution
0.1kHz
Standard frequency
5kHz、100kHz
Pulse group duration
0.001~2550.000ms
Pulse group period
300ms ( 0.15~99.99 s)
Test duration
1s~9999s
Direct output mode
Through high-voltage coaxial connector
Phase synchronous
0°~359°(45 HZ~ 65 HZ)
(synchronous, automatic, asynchronous))
Coupling
Built-in 3-phase 5-wire coupling
UAC MAX 690V /200A UDC MAX 1000V/200A